Pesquisa de referências

The Effects of phase control materials on hand skin temperature within gloves of soccer goalkeepers

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071502197</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418123156.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">020130e20001001gbr||||    | |00010|eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080081843</subfield>
      <subfield code="a">Purvis, A. J.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="4">
      <subfield code="a">The Effects of phase control materials on hand skin temperature within gloves of soccer goalkeepers</subfield>
      <subfield code="c">A. J. Purvis and N. T. Cable</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">In soccer, goalkeepers routinely wear gloves that may restrict heat loss from the hands and cause thermal discomfort. In order to alleviate this problem phase control materials (PCMs) have been incorporated into gloves to reduce heat load inside the glove, thereby maintaining a comfortable temperature. The aim of this study was to assess the efficacy of these materials during a simulation of goalkeeping activities</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080578497</subfield>
      <subfield code="a">Termorregulación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080601836</subfield>
      <subfield code="a">Guantes de protección</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080541118</subfield>
      <subfield code="a">Fútbol</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080556600</subfield>
      <subfield code="a">Sudoración</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080547127</subfield>
      <subfield code="a">Estudios</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080039301</subfield>
      <subfield code="a">Cable, N. T.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Ergonomics</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Ergonomics</subfield>
      <subfield code="d">London and Washington</subfield>
      <subfield code="g">Vol. 43, nº 10, October 2000 ; p. 1480-1488</subfield>
    </datafield>
  </record>
</collection>