Search

Shakin' aIl over : the importance of earthquake protection for sprinkler system

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cab a2200000   4500</leader>
    <controlfield tag="001">MAP20130020228</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20130710111422.0</controlfield>
    <controlfield tag="008">130710e20130601esp|||p      |0|||b|spa d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">813.2</subfield>
    </datafield>
    <datafield tag="100" ind1=" " ind2=" ">
      <subfield code="0">MAPA20130008462</subfield>
      <subfield code="a">Klaus, Matt</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Shakin' aIl over</subfield>
      <subfield code="b">: the importance of earthquake protection for sprinkler system</subfield>
      <subfield code="c">Matt Klaus</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Earthquake protection, as required by NFPA 13, Section 9.3, is designed to limit the impact of this differential movement so that the sprinkler system can function as intended after, and potentially during, the seismic event. NFPA 13 uses several design concepts to limit the impact of differential movement, including limiting piping stress through the use of flexible fittings and clearances</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080620424</subfield>
      <subfield code="a">Seguridad contra incendios</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080608415</subfield>
      <subfield code="a">Rociadores automáticos</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080556792</subfield>
      <subfield code="a">Terremotos</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080584771</subfield>
      <subfield code="a">Diseño de sistemas</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20130008479</subfield>
      <subfield code="a">NFPA 13</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080547646</subfield>
      <subfield code="a">Impactos</subfield>
    </datafield>
    <datafield tag="710" ind1="0" ind2=" ">
      <subfield code="0">MAPA20080432614</subfield>
      <subfield code="a">NFPA</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20077000468</subfield>
      <subfield code="t">NFPA Journal</subfield>
      <subfield code="d">Miami : NFPA</subfield>
      <subfield code="x">1054-8793</subfield>
      <subfield code="g">03/06/2013 May-June 2013 </subfield>
    </datafield>
  </record>
</collection>