Search

Machines portatives d'assemblage : intensité des vibrations induites : problèmes de santé liés à leur utilisation

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071016022</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20200603155214.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">931130e19910101fra||||    | |00010|fre d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800002256</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Machines portatives d'assemblage</subfield>
      <subfield code="b">: intensité des vibrations induites : problèmes de santé liés à leur utilisation</subfield>
      <subfield code="c">S. Kihlberg... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">La machine portative la plus fréquemment utilisée sur les chaînes de montage de camions est la clef à chocs. Un étude technique et médicale a fait apparaître que les inconvénients de cette machine étaient inacceptables. Il a été procédé à différentes mesures sur un échantillon des machines les plus souvent utilisées sur les chaînes de montage: intensité vibratoire, durée d'exposition aux vibrations et fréquence des différents types de prise sur la poignée avec chacun des mains</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080600488</subfield>
      <subfield code="a">Contaminantes físicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080561048</subfield>
      <subfield code="a">Vibraciones</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080548056</subfield>
      <subfield code="a">Máquinas</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080602376</subfield>
      <subfield code="a">Máquinas y herramientas</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080619480</subfield>
      <subfield code="a">Enfermedades profesionales</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080590925</subfield>
      <subfield code="a">Fenómeno de Raynaud</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080617219</subfield>
      <subfield code="a">Industria automovilística</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080047658</subfield>
      <subfield code="a">Kihlberg, S.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Cahiers de notes documentaires</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Cahiers de notes documentaires</subfield>
      <subfield code="d">Paris</subfield>
      <subfield code="g">nº 142, 1er. trimestre 1991 ; p. 87-92</subfield>
    </datafield>
  </record>
</collection>