Search

Chromates métalliques et sulfure de cadmium : évaluation de l'exposition professionnelle dans trois ateliers de fabrication de pigments minéraux

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071016550</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418114653.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">931223e19900701fra||||    | |00010|fre d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800002582</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Chromates métalliques et sulfure de cadmium</subfield>
      <subfield code="b">: évaluation de l'exposition professionnelle dans trois ateliers de fabrication de pigments minéraux</subfield>
      <subfield code="c">M. Hery... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Une évaluation des expositions atmosphériques aux produits chimiques a été effectuée chez deux fabricants de chromates et un fabricant de sulfure de cadmium. L'ensemble des résultats obtenus montre que les valeurs limites d'exposition, qui sont fixées à des niveaux très bas pour ces produits suspectés de cancérogénicité pour l'homme, sont largement dépassées, même dans le cas où des protections individuelles du type masques anti-poussières sont utilisées. Seule, une évolution des procédés de fabrication vers l'automatisation permettra de produire ces composés dans des conditions d'hygiène industrielle satisfaisantes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080588946</subfield>
      <subfield code="a">Ambiente de trabajo</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080540463</subfield>
      <subfield code="a">Cadmio</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080538569</subfield>
      <subfield code="a">Cromo</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080591960</subfield>
      <subfield code="a">Métodos de análisis</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560973</subfield>
      <subfield code="a">Valores TLV</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080628048</subfield>
      <subfield code="a">Equipos de protección individual</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080548094</subfield>
      <subfield code="a">Máscaras</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080571566</subfield>
      <subfield code="a">Casos prácticos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080639310</subfield>
      <subfield code="a">Francia</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080001629</subfield>
      <subfield code="a">Héry, M.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Cahiers de notes documentaires</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Cahiers de notes documentaires</subfield>
      <subfield code="d">Paris</subfield>
      <subfield code="g">nº 140, 3e. trimestre 1990 ; p. 575-581</subfield>
    </datafield>
  </record>
</collection>