Search

The Determination of airborne methyl ethyl ketone peroxide in the glass reinforced plastics industry

Fichero PDF / PDF file
MAP20071017263
Purnell, C.J.
The Determination of airborne methyl ethyl ketone peroxide in the glass reinforced plastics industry / C.J. Purnell, G.L. Martin and H. Wolfson
Sumario: A method is described for the determination of methyl ethyl ketone peroxide in air with a minimum detection limit of 0.025 ppm. The samples air is drawn through an acid solution of titanium tetrachloride and the absorvance of the peroxytitanyl complex is measured at 415 nm. The calibration graph of absrovance vs concentration for a 100 l. air sample over the range 0.025-5 ppm is linear. Interferences from other compounds such as ozone, styrene or acetone are not apparent
En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 4, 1979 ; p. 383-387
1. Higiene industrial . 2. Contaminantes químicos . 3. Sustancias tóxicas y peligrosas . 4. Metil-etil-cetona . 5. Contaminación atmosférica . 6. Control de contaminantes . 7. Métodos de análisis . 8. Industria del plástico . I. Martin, G.L. . II. Wolfson, H. . III. Title. IV. Título: The Annals of occupational hygiene.