Search

The Behaviour of fibrous filter media in dust respirators

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<nonSort xml:space="preserve">The  </nonSort>
<title>Behaviour of fibrous filter media in dust respirators</title>
</titleInfo>
<titleInfo type="alternative">
<title>The Annals of occupational hygiene</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080021146">
<namePart>Brown, R.C.</namePart>
<nameIdentifier>MAPA20080021146</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1980</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The mechanical behaviour of filters is briefly reviewed, without complicated mathematics, and the general principles illustrate that large area filters of fine fibres perform well. The various types of electrostatic filter material avaible for use in respirators at the present are illustrated, one of which is a filter made of fine charged fibres, combining the advantages of the best type of mechanical filter with the beneficial efects of electric charge on the fibres. Existing filter test methods are outlined and the need for a standard test of electrostatic filters to assess the likely performance in service is discussed</abstract>
<note type="statement of responsibility">R.C. Brown</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080541026">
<topic>Fibras</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539566">
<topic>Polvo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080543969">
<topic>Filtros</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601393">
<topic>Equipos respiratorios</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>The Annals of occupational hygiene</title>
</titleInfo>
<originInfo>
<publisher>Oxford [etc.]</publisher>
</originInfo>
<part>
<text>nº 4, 1980 ; p. 367-380</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940214</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418115024.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071017353</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>