Search

Comparison of three tracer gases for determining ventilation effectiveness and capture efficiency

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Comparison of three tracer gases for determining ventilation effectiveness and capture efficiency</title>
</titleInfo>
<titleInfo type="alternative">
<title>The Annals of occupational hygiene</title>
</titleInfo>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080030544">
<namePart>Niemelä, R.</namePart>
<nameIdentifier>MAPA20080030544</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1991</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Sulphur hexafluoride, nitrous oxide and helium were compared as tracer gases for determining the mean residence time in a test room and the capture efficiency of a local exhaust hood. The mixtures of tracer gases were fed into the inlet air and two sites in the test room with and without mixing of room air. It dertermined the capture efficiency by releasing the tracer gases through the cylindrical injection system in front of the exhaust hood at different capture velocities under various cross-draught conditions. The results of the measurements in the test room showed good agreement between the different tracer gases except in the stagnant zone. The first capture efficiency measurements indicated that SF6, the heaviest gas, gave smaller values obviously due to imcomplete mixing of tracer gases. However, the difference disappeared when mixing of the tracer gas was speeded up pumping extra air or by modifying the injection system</abstract>
<note type="statement of responsibility">R. Niemelä... [et al.]</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080565817">
<topic>Gases tóxicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080613655">
<topic>Control de contaminantes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616441">
<topic>Contaminación atmosférica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080538934">
<topic>Helio</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080566753">
<topic>Oxido nitroso</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080606411">
<topic>Hexafluoruro de azufre</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080612597">
<topic>Sistemas de ventilación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560997">
<topic>Ventilación</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>The Annals of occupational hygiene</title>
</titleInfo>
<originInfo>
<publisher>Oxford [etc.]</publisher>
</originInfo>
<part>
<text>nº 4, August 1991 ; p. 405-417</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940311</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418115226.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071017881</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>