Search

Pulmonary clearance of fibrous and angular SiC particulates in the sheep model of pneumoconiosis

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071017932</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115237.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940315e19921001gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800003072</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">873</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Pulmonary clearance of fibrous and angular SiC particulates in the sheep model of pneumoconiosis</subfield>
      <subfield code="c">A. Dufresne... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Carborundum pneumoconiosis is now recognized as an occupational lung disease with specific pathological features. These were previously reproduced in the sheep model of pneumoconiosis with fibrous SiC but not with angular SiC. To futher document this question, the pulmonary retention in the sheep of the two morphological types was studied. Animals were injected in the tracheal lobe with equal mass (100 mg) of particulates prepared from SiC materials taken in the field. Particles were measured by analytical transmission electron microscopy in samples of bronchoalveolar lavage fluids (BAL) obtained at months 2, 4, 6 and 8 after the injection. They were also measured in samples of lung parenchyma obtained at month 8. Measurements in BAL and in lung samples both indicated a much lower retention for fibrous than for angular SiC. The retention rate in lung parendhyma at month 8 was 30 times lower for fibrous SiC. The half-life of decrease of concentrations was 3.4 times shorter for fibrous SiC. Other data in the literature support the notion that fine fibres are cleared more effectively than coarser angular particles</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080576615</subfield>
      <subfield code="a">Medicina laboral</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080619480</subfield>
      <subfield code="a">Enfermedades profesionales</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080583934</subfield>
      <subfield code="a">Carburo de silicio</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080610579</subfield>
      <subfield code="a">Enfermedades pulmonares</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080566593</subfield>
      <subfield code="a">Neumoconiosis</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080551797</subfield>
      <subfield code="a">Muestreos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080591960</subfield>
      <subfield code="a">Métodos de análisis</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080042134</subfield>
      <subfield code="a">Dufresne, A.</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 5, October 1992 ; p. 519-530</subfield>
    </datafield>
  </record>
</collection>