Ozone removal capability of a welding fume respirator containing activated charcoal / Alan R. Johnston, James F. Dyrud and Young Tzung Shih
Sumario: Development of air purifying respirators for protection against ozone has been slowed by concerns about oxidation of charcoal and other available sorbents. The suitability of a charcoal sorbent for low concentrations of ozone was evaluated as a part of the development of a half-mask air purifying respirator designed for welding fumes and ozone. Testing of the respirator confirmed that charcoal can be a suitable sorbent for low levels of ozone
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 50, nº 9, September 1989 ; p. 451-454
1. Higiene industrial . 2. Contaminantes químicos . 3. Humos tóxicos . 4. Soldadura . 5. Ozono . 6. Equipos respiratorios . 7. Carbón activado . I. Dyrud, James F. . II. Tzung Shih, Young . III. Title. IV. Título: American Industrial Hygiene Association journal.