Section: ArticlesTitle: Measurement of the leakage and fit factor of a filtering facepiece by continuous monitoring of pressure pulsations / R.C. Brown, N.P. VaughanAuthor: Brown, R.C.Notes: Sumario: A novel method for measuring the fit factor of filtering facepiece respirators is described. Measurement is made by the continual monitoring of the pressure produced by a volume of air injected into the respirator cavity, and withdrawn so that the added volume varies sinusoidally with timeRelated records: En: American Industrial Hygiene Association journal. - Fairfax, Virginia. - Vol. 54, nº 8, August 1993 ; p. 409-416Materia / lugar / evento: Higiene industrialMáscarasEquipos respiratoriosMascarillas autofiltrantesFiltrosMétodos de análisisMuestreosOtros autores: Vaughan, Nicholas P. Secondary titles: Título: American Industrial Hygiene Association journal Other categories: 872Rights: In Copyright (InC)