A Correlation of the wet-bulb globe temperature and botsball heat stress indexes for industry

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071020175
003  MAP
005  20080418120118.0
007  hzruuu---uuuu
008  940627e19920301usa|||| | |00010|eng d
035  ‎$a‎6800013477
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080128784‎$a‎Dernedde, Edgar
24512‎$a‎A Correlation of the wet-bulb globe temperature and botsball heat stress indexes for industry‎$c‎Edgar Dernedde
520  ‎$a‎In the present study, new heat transfer analyses were made by using established heat and mass transfer coefficients for both heat stress instruments. Calculations of wet-bulb glove temperature (WBGT) and boltsball temperature (BBT) were made over a wide range of conditions simulating different industrial environments. The two heat stress indexes were then correlated by polynomial and multiple regression equations
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080600488‎$a‎Contaminantes físicos
65011‎$0‎MAPA20080538330‎$a‎Calor
65011‎$0‎MAPA20080560768‎$a‎Temperatura
65011‎$0‎MAPA20080560799‎$a‎Termometría
65011‎$0‎MAPA20080568894‎$a‎Estrés térmico
65011‎$0‎MAPA20080554125‎$a‎Ecuaciones
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 53, nº 3, March 1992 ; p. 169-174