Search

Permeation testing of protective gloves by using two different permeation cells in an open-loop system (neoprene-toluene)

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Permeation testing of protective gloves by using two different permeation cells in an open-loop system (neoprene-toluene)</title>
</titleInfo>
<titleInfo type="alternative">
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080140908">
<namePart>Mellström, G.A.</namePart>
<nameIdentifier>MAPA20080140908</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080075156">
<namePart>Landersjö, L.</namePart>
<nameIdentifier>MAPA20080075156</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080063009">
<namePart>Boman, Anders</namePart>
<nameIdentifier>MAPA20080063009</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<dateIssued encoding="marc">1991</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Two permeation test cells of different sizes were used in a study of the permeation of toluene through two neoprene gloves and special neoprene sheet stock. The purpose of the present study was to extend the findings obtained in that study by investigating how and to what extent the changing of collecting gas flow rate in two permeation cells with different sizes and designs would affect the measured values for breakthrough time and steady-state permeation rate by using another solvent with different physicochemical properties</abstract>
<note type="statement of responsibility">G.A. Mellström, L. Landersjö and A.S. Boman</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601836">
<topic>Guantes de protección</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080545574">
<topic>Tolueno</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080566821">
<topic>Permeabilidad</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080548346">
<topic>Neopreno</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539948">
<topic>Tests</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<originInfo>
<publisher>Akron, Ohio</publisher>
</originInfo>
<part>
<text>Vol. 52, nº 8, August 1991 ; p. 309-314</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940704</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120133.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071020222</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>