Search

Electrostatic effects in asbestos sampling I : experimental measurements

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071020483
003  MAP
005  20080418120234.0
007  hzruuu---uuuu
008  940712e19900201usa|||| | |00010|eng d
035  ‎$a‎6800013601
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080090746‎$a‎Baron, Paul A.
24510‎$a‎Electrostatic effects in asbestos sampling I‎$b‎: experimental measurements‎$c‎Paul A. Baron and Gregory J. Deye
520  ‎$a‎Electrostatic charge can cause errors during sampling of airborne asbestos fibers and other particles. The change in particle trajectories caused by charge effects during sampling can result in nonuniform deposits on the collecting filter surface and net loss of sample. The degree of these electrostatic effects depends on particle charge, sampler charge, sampler conductivity, and sampling flow rate and direction. The purpose of this research was to evaluate the dependence of sampling efficiency and sample uniformity on these variables. Humidity has been postulated as a primary determinant of particle charge during aerosol generation
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080542832‎$a‎Amianto
65011‎$0‎MAPA20080607609‎$a‎Partículas ambientales
65011‎$0‎MAPA20080601041‎$a‎Electricidad estática
65011‎$0‎MAPA20080544195‎$a‎Humedad
65011‎$0‎MAPA20080551797‎$a‎Muestreos
7001 ‎$0‎MAPA20080160609‎$a‎Deye, Gregory J.
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 51, nº 2, February 1990 ; p. 51-62