Search

Dead space in the breathing apparatus; interaction with ventilation

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Dead space in the breathing apparatus; interaction with ventilation</title>
</titleInfo>
<titleInfo type="alternative">
<title>Ergonomics</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080151577">
<namePart>Warkander, D.E.</namePart>
<nameIdentifier>MAPA20080151577</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080170042">
<namePart>Lundgren, C.E.G.</namePart>
<nameIdentifier>MAPA20080170042</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1995</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Dead space in breathing apparatus may cause increased ventilation and/or CO2 retention. Interactions between ventilation and dead space tested in the breathing apparatus of three divers: a full face mask with an oro-nasal cul (AGA), a full face mask without an oro-nasal cup (EXO-26) but designed to minimize dead space, and one mouthpiece. Comparisons of the mean inspired PCO2 to the maximum values considered acceptable by various organizations showed that the mouthpiece was always acceptable, THe AGA mask was marginally acceptable or better, while sometimes the EXO-26 was not acceptable</abstract>
<note type="statement of responsibility">D.E. Warkander and C.E.G. Lundgren</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080550653">
<topic>Ergonomía</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080538316">
<topic>Buceo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601393">
<topic>Equipos respiratorios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080540814">
<topic>Diseño</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560997">
<topic>Ventilación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080564285">
<topic>Submarinismo</topic>
</subject>
<classification authority="">875</classification>
<relatedItem type="host">
<titleInfo>
<title>Ergonomics</title>
</titleInfo>
<originInfo>
<publisher>London and Washington</publisher>
</originInfo>
<part>
<text>Vol. 38, nº 9, September, 1995 ; p. 1745-1758</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">960624</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418121138.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071025152</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>