Búsqueda

A Short-term solid sorbent determination of hydrazoic acid in air

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071020139
003  MAP
005  20080418120111.0
007  hzruuu---uuuu
008  940701e19910101usa|||| | |00010|eng d
035  ‎$a‎6800013263
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080145033‎$a‎Puskar, Mark A.
24512‎$a‎A Short-term solid sorbent determination of hydrazoic acid in air‎$c‎Mark A. Puskar, Scott M. Fergon and Lawrence H. Hecker
520  ‎$a‎A sampling aanlytical method for the measurement of hydrazoic acid (HN3) at the short-term ceiling limit was developed and validated under both laboratory and field conditions. The HN3 was collected on sodium hydroxide pretreated Orbo 52 silica gel tubes at a sampling flow rate of 1.0 L/min for 15 min
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080574413‎$a‎Ácido hidrazoico
65011‎$0‎MAPA20080551797‎$a‎Muestreos
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
65011‎$0‎MAPA20080600662‎$a‎Cromatografía líquida
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
7001 ‎$0‎MAPA20080162092‎$a‎Fergon, Scott M.
7001 ‎$0‎MAPA20080244958‎$a‎Hecker, Lawrence H.
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 52, nº 1, January 1991 ; p. 14-19