Simplified pressure method for respirator fit testing
<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Simplified pressure method for respirator fit testing</title>
</titleInfo>
<titleInfo type="alternative">
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080000639">
<namePart>Han, D.</namePart>
<nameIdentifier>MAPA20080000639</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<dateIssued encoding="marc">1991</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The main goal of this study was, therefore, to develop a simplified pressure method that is not affected by the respirator cavity volume and the pliability of the respirator body. A simplified pressure method has been developed for fit testing air-purifying respirators. The aerosol tests gave higher values of fit</abstract>
<note type="statement of responsibility">D. Han... [et al.]</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080549534">
<topic>Aerosoles</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601393">
<topic>Equipos respiratorios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539948">
<topic>Tests</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591960">
<topic>Métodos de análisis</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080551797">
<topic>Muestreos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080621254">
<topic>Detectores de contaminantes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080613655">
<topic>Control de contaminantes</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<originInfo>
<publisher>Akron, Ohio</publisher>
</originInfo>
<part>
<text>Vol. 52, nº 8, August 1991 ; p. 305-308</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940704</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120133.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071020221</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>