Effects of humidity and contaminant concentration on respirator cartridge breakthrough
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020475</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120232.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940711e19900401usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013593</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080152628</subfield>
<subfield code="a">Yoon, Young Hee</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Effects of humidity and contaminant concentration on respirator cartridge breakthrough</subfield>
<subfield code="c">Young Hee Yoon and James H. Nelson</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">This study emphasizes the potential application of the original model to the assessment of the effects of humidity and contaminant assault concentration on contaminant breakthrough in the breakthrough region of approximately 0-50%. The study specifically addresses a contaminant concentration range of 250-2000 ppm and a relative humidity range of dry to 80% for the environment in which the respirator is used. The cartridge preconditioning humidity is considered fixed at a value of 50% relative humidity. The contaminants investigated are benzene and methyl chloroform</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080572822</subfield>
<subfield code="a">Metilcloroformo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080543112</subfield>
<subfield code="a">Benceno</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601393</subfield>
<subfield code="a">Equipos respiratorios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080544195</subfield>
<subfield code="a">Humedad</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080172688</subfield>
<subfield code="a">Nelson, James H.</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 51, nº 4, April 1990 ; p. 202-209</subfield>
</datafield>
</record>
</collection>