Búsqueda

Cuves de traitement de surface : performance de captage de fentes d'aspiration

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071026751</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418121454.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">970122e19961001fra||||    | |00010|fre d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Cuves de traitement de surface</subfield>
      <subfield code="b">: performance de captage de fentes d'aspiration</subfield>
      <subfield code="c">R. Régnier... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">The INRS carried out an experimental study to determine the exhaust performances of lateral exhaust slots on surface treatment tanks. Full-scale models of different width/length ratios were tested in a wind tunnel simulating controlled air draught intensity and direction in an exhaust flowrate range covering the values generally recommended</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080588946</subfield>
      <subfield code="a">Ambiente de trabajo</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080620721</subfield>
      <subfield code="a">Tratamiento de superficies</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080544577</subfield>
      <subfield code="a">Metales</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560997</subfield>
      <subfield code="a">Ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080612597</subfield>
      <subfield code="a">Sistemas de ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080639310</subfield>
      <subfield code="a">Francia</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080032289</subfield>
      <subfield code="a">Regnier, R.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Cahiers de notes documentaires</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Cahiers de notes documentaires</subfield>
      <subfield code="d">Paris</subfield>
      <subfield code="g">nº 165, 4e. trimestre 1996 ; p. 425-441</subfield>
    </datafield>
  </record>
</collection>