Búsqueda

Combustible storage

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071502221</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418123204.0</controlfield>
    <controlfield tag="008">000000e20011101usa||||    | |00010|eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">816</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080010126</subfield>
      <subfield code="a">Comeau, Ed</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Combustible storage</subfield>
      <subfield code="c">Ed Comeau and Robert Duval</subfield>
    </datafield>
    <datafield tag="520" ind1="8" ind2=" ">
      <subfield code="a">On August 2, 2000, Phoenix, Arizona, experienced one of the largest fires in its history in a multi-tenanted  building containing Central Garden and Pet Suply and Cardinal Distributors. By the time fire crews extinguished the blaze the next day, the building was a smoldering ruin. A number of civilians had to be evacuated from the surrounding neighborhood, and the loss is estimated to be in the hundreds of millions of dollars. What caused the fire to become so large? Investigation into the cause of the fire continues as of the writing</subfield>
    </datafield>
    <datafield tag="610" ind1="2" ind2="1">
      <subfield code="0">MAPA20080442705</subfield>
      <subfield code="a">Stratosphere Tower</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080620424</subfield>
      <subfield code="a">Seguridad contra incendios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080568863</subfield>
      <subfield code="a">Estados Unidos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080608613</subfield>
      <subfield code="a">Siniestros de incendio</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080597412</subfield>
      <subfield code="a">Líquidos inflamables</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="1">
      <subfield code="0">MAPA20080599898</subfield>
      <subfield code="a">Almacenes de líquidos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080621599</subfield>
      <subfield code="a">Investigación de accidentes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613242</subfield>
      <subfield code="a">Causas de los accidentes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080571566</subfield>
      <subfield code="a">Casos prácticos</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080067564</subfield>
      <subfield code="a">Duval, Robert</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">NFPA Journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20077000468</subfield>
      <subfield code="t">NFPA Journal</subfield>
      <subfield code="d">Quincy, Massachusetts</subfield>
      <subfield code="g">November-December 2001 ;  p. 70-73</subfield>
    </datafield>
  </record>
</collection>