Búsqueda

Limites de la surveillance biologique des polychlorobiphényles (P.C.B.) lors d'une exposition accidentelle

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071016682</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20200527152536.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">930110s1992    fra||||    | |00010|fre d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800002661</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Limites de la surveillance biologique des polychlorobiphényles (P.C.B.) lors d'une exposition accidentelle</subfield>
      <subfield code="c">M. Sarthou-Moutengou... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A l'occasion d'une explosion non suivi d'incendie survenue sur un appareil isolé au pyralène ont été réalisées des investigations cliniques, biologiques et environnementales. Les auteurs font les observations suivantes: l'exposition liée à l'accident en ce qui concerne le pyralène et ses dérivés toxiques semble avoir été nulle; la trace d'une exposition professionnelle ancienne est mise en évidence chez le personnel électricien de l'entreprise qui ne manipule plus de pyralène depuis 1985; le taux des P.C.B. plasmatiques est, en cas d'exposition accidentelle, considéré comme un marqueur biologique d'une intoxication éventuelle par ses dérivés de thermolyse. La valeur de ce marquage semble devoir faire l'objet de réserves en ce que: chez du personnel professionnellement exposé les taux plasmátiques habituels peuvent ne pas être négligeables; la fiabilité du dosage, dont les réponses varient d'un jour à l'autre, ne semble pas parfaite</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080576615</subfield>
      <subfield code="a">Medicina laboral</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080536800</subfield>
      <subfield code="a">PCB</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613655</subfield>
      <subfield code="a">Control de contaminantes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560850</subfield>
      <subfield code="a">Toxicología</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080577162</subfield>
      <subfield code="a">Plasma sanguíneo</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080570484</subfield>
      <subfield code="a">Riesgo laboral</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080569334</subfield>
      <subfield code="a">Intoxicaciones</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560973</subfield>
      <subfield code="a">Valores TLV</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080293123</subfield>
      <subfield code="a">Sarthou-Moutengou, M.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Archives des maladies professionnelles et de médecine du travail</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Archives des maladies professionnelles et de médecine du travail</subfield>
      <subfield code="d">Paris [etc.]</subfield>
      <subfield code="g">nº 1, 1992 ; p. 5-11</subfield>
    </datafield>
  </record>
</collection>