Búsqueda

A Simple, sensitive technique for personal and environmental sampling and analysis of lead alkyl vapours in air

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017196
003  MAP
005  20080418114951.0
007  hzruuu---uuuu
008  940207e19780301gbr|||| | |00010|eng d
035  ‎$a‎6800003100
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080022266‎$a‎Coker, D.T.
24512‎$a‎A Simple, sensitive technique for personal and environmental sampling and analysis of lead alkyl vapours in air‎$c‎D.T. Coker
520  ‎$a‎A technique is described for collecting lead alkyl vapour in air by sampling through a small vapour adsorption tube packed with porous polymer beads. Volumes of at least 10.1 of air can be sampled without breakthrough losses, allowing 8-h shift sampling using one tube and low flow rate personal sampling pump. Tubes can be stored for several days without loss of sample; they can be analysed in 2 min. by heat desorption directly into an atomic absorption spectrometer burner. The analysis is specific for lead alkyls and detection limits are around 0.01 for TLV or 10-20 ng lead
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080577179‎$a‎Plomo tetraetilo
65011‎$0‎MAPA20080545673‎$a‎Vapores
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
65011‎$0‎MAPA20080560973‎$a‎Valores TLV
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 1, March 1978 ; p. 33-38