Búsqueda

The Determination of airborne methyl ethyl ketone peroxide in the glass reinforced plastics industry

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017263
003  MAP
005  20080418115008.0
007  hzruuu---uuuu
008  940210s1979 gbr|||| | |00010|eng d
035  ‎$a‎6800003167
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080081829‎$a‎Purnell, C.J.
24514‎$a‎The Determination of airborne methyl ethyl ketone peroxide in the glass reinforced plastics industry‎$c‎C.J. Purnell, G.L. Martin and H. Wolfson
520  ‎$a‎A method is described for the determination of methyl ethyl ketone peroxide in air with a minimum detection limit of 0.025 ppm. The samples air is drawn through an acid solution of titanium tetrachloride and the absorvance of the peroxytitanyl complex is measured at 415 nm. The calibration graph of absrovance vs concentration for a 100 l. air sample over the range 0.025-5 ppm is linear. Interferences from other compounds such as ozone, styrene or acetone are not apparent
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080625054‎$a‎Sustancias tóxicas y peligrosas
65011‎$0‎MAPA20080581275‎$a‎Metil-etil-cetona
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080613655‎$a‎Control de contaminantes
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
65011‎$0‎MAPA20080606626‎$a‎Industria del plástico
7001 ‎$0‎MAPA20080050214‎$a‎Martin, G.L.
7001 ‎$0‎MAPA20080035464‎$a‎Wolfson, H.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 4, 1979 ; p. 383-387