<dc:description xml:lang="es">Sumario: The design, testing and use of a 23 mm internal diameter cyclone for sampling of respirable dust are described. Calibration of the cyclone showed that the size selection characteristic of the cyclone gave a close match of the BMRC d50 at a flow rate of 9.2 l. min-1. On this basis, field trials were conducted at this flow rate and measurements of respirable dust and respirable silica emissions from a number of mineral processing stacks are included</dc:description>
<dc:identifier>https://documentacion.fundacionmapfre.org/documentacion/publico/es/bib/45818.do</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights xml:lang="es">InC - http://rightsstatements.org/vocab/InC/1.0/</dc:rights>
<dc:subject xml:lang="es">Higiene industrial</dc:subject>
<dc:subject xml:lang="es">Contaminación atmosférica</dc:subject>
<dc:subject xml:lang="es">Control de la contaminación</dc:subject>
<dc:subject xml:lang="es">Polvo</dc:subject>
<dc:subject xml:lang="es">Muestreador</dc:subject>
<dc:subject xml:lang="es">Muestreos</dc:subject>
<dc:type xml:lang="es">Artículos y capítulos</dc:type>
<dc:title xml:lang="es">A Higher-flow rate cyclone for determination of respirable dust</dc:title>
<dc:title xml:lang="es">Título: The Annals of occupational hygiene</dc:title>
<dc:relation xml:lang="es">En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 1, 1987 ; p. 39-52</dc:relation>
</rdf:Description>
</rdf:RDF>