Búsqueda

Activated carbon filters in air cleaning processes. II : prediction of breakthrough times and capacities from laboratory studies of model filters

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071017766</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115158.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940308e19900201gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800003081</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080008741</subfield>
      <subfield code="a">Balieu, E.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Activated carbon filters in air cleaning processes. II</subfield>
      <subfield code="b">: prediction of breakthrough times and capacities from laboratory studies of model filters</subfield>
      <subfield code="c">E. Balieu and E. Bjarnov</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A method based on studies of model filters is suggested for prediction of breakthrough times and capacities of activated carbon filters in local exhaust ventilation units. The method involves the determination of three penetration curve parameters from testing of the model filters. The results indicate that the filter under investigation will have a relatively short breakthrough time under normal working conditions and it is recommended that the amount of activated carbon should be substantially increased</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080625016</subfield>
      <subfield code="a">Sistemas de limpieza del aire</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080571528</subfield>
      <subfield code="a">Carbón activado</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080543969</subfield>
      <subfield code="a">Filtros</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560997</subfield>
      <subfield code="a">Ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080612597</subfield>
      <subfield code="a">Sistemas de ventilación</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080020576</subfield>
      <subfield code="a">Bjarnov, E.</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 1, February 1990 ; p. 1-11</subfield>
    </datafield>
  </record>