Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Sección: ArtículosTítulo: Activated carbon filters in air cleaning processes. II : prediction of breakthrough times and capacities from laboratory studies of model filters / E. Balieu and E. BjarnovAutor: Balieu, E.Notas: Sumario: A method based on studies of model filters is suggested for prediction of breakthrough times and capacities of activated carbon filters in local exhaust ventilation units. The method involves the determination of three penetration curve parameters from testing of the model filters. The results indicate that the filter under investigation will have a relatively short breakthrough time under normal working conditions and it is recommended that the amount of activated carbon should be substantially increasedRegistros relacionados: En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 1, February 1990 ; p. 1-11Materia / lugar / evento: Higiene industrialContaminación atmosféricaSistemas de limpieza del aireCarbón activadoFiltrosVentilaciónSistemas de ventilaciónOtros autores: Bjarnov, E. Títulos secundarios: Título: The Annals of occupational hygiene Otras clasificaciones: 872Derechos: In Copyright (InC)