Sección: ArtículosTítulo: Effect of cowl on air samples for amosite in the workplace and in the laboratory / S.N. Tannahill, M.H. Jackson and R.J. WilleyAutor: Tannahill, S.N.Notas: Sumario: This paper describes work carried out in the laboratory and in the workplace, to quantify any difference which may be caused by the use of an aluminium cowl when sampling amosite. Simultaneous side-by-side comparisons were made of samples collected using an aluminium cowl an open Gelman sampling head. On the basis of both sets of results it appears that the use of an aluminium conducting cowl during the sampling of amosite does not have a significant effect on the measured fibre concentrations within the range 0.04-31 f ml exp.(-1) and 0.33-2.25 f ml exp.(-1) for static and personal samples, respectivelyRegistros relacionados: En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 5, October 1990 ; p. 521-527Materia / lugar / evento: Higiene industrialContaminantes químicosAmositaAluminioControl de la contaminaciónContaminación atmosféricaMuestreosLaboratoriosAmbiente de trabajoEnsayosOtros autores: Jackson, M.H. Willey, R.J. Títulos secundarios: Título: The Annals of occupational hygiene Otras clasificaciones: 872Derechos: In Copyright (InC)