Búsqueda

A Feasibility study of quantitative respirator fit testing by controlled negative pressure

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071020312
003  MAP
005  20080418120151.0
007  hzruuu---uuuu
008  940701e19910401usa|||| | |00010|eng d
035  ‎$a‎6800013524
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080316594‎$a‎Crutchfield, Clifton D.
24512‎$a‎A Feasibility study of quantitative respirator fit testing by controlled negative pressure‎$c‎Clifton D. Crutchfield, Martin P. Eroh, Mark D. Van Ert
520  ‎$a‎The feasibility of using a direct measure of respirator leakage flow rate as a quantitative index of respirator face seal fit has been explored through the use of a new controlled negative pressure method. The method is based on exhausting air from a temporarily sealed respirator facepiece at a rate sufficient to generate and then sustain a constant negative pressure inside the facepiece while the wearer holds his breath
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080601393‎$a‎Equipos respiratorios
65011‎$0‎MAPA20080619831‎$a‎Mascarillas autofiltrantes
65011‎$0‎MAPA20080548094‎$a‎Máscaras
65011‎$0‎MAPA20080586355‎$a‎Métodos de control
65011‎$0‎MAPA20080539948‎$a‎Tests
7001 ‎$0‎MAPA20080130145‎$a‎Eroh, Martin P.
7001 ‎$0‎MAPA20080161743‎$a‎Ert, Mark D. van
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 52, nº 4, April 1991 ; p. 172-176