Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
MAP20071020332Bishop, Phillip A.Comparisons of air and liquid personal cooling for intermittent heavy work in moderate temperatures / Phillip A. Bishop, Sarah A. Nunneley, Stefan H. ConstableSumario: Personal microenvironmental cooling has been used to enhance safety and extend the work capacity of laborers wearing protective clothing. Previous studies of air and liquid cooling have used either very low work rates or high environmental temperatures. The purpose of this research was to examine the efficacy of intermittent personal cooling during rest and to compare liquid and air cooling systems in subjects engaged in hard workEn: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 52, nº 9, September 1991 ; p. 393-3971. Higiene industrial. 2. Contaminantes físicos. 3. Temperatura. 4. Calor. 5. Ropas. 6. Refrigerantes. I. Nunneley, Sarah A.. II. Constable, Stefan H.. III. Título. IV. Título: American Industrial Hygiene Association journal.