Búsqueda

A New technique to calibrate optical particle counters aerodynamically

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<nonSort xml:space="preserve">A  </nonSort>
<title>New technique to calibrate optical particle counters aerodynamically</title>
</titleInfo>
<titleInfo type="alternative">
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080009892">
<namePart>Chen, B.T.</namePart>
<nameIdentifier>MAPA20080009892</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080017477">
<namePart>Tang, J.A.</namePart>
<nameIdentifier>MAPA20080017477</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080007898">
<namePart>Yeh, H.C.</namePart>
<nameIdentifier>MAPA20080007898</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<dateIssued encoding="marc">1990</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The authors developed a technique using a two-stage, Lovelace virtual impactor to classify aerodynamically a monodisperse aerosol for calibration of OPCs (optical particle counter). The advantages of this method are that (1) classified aerosols can be introduced directly into the OPC to compare the optical response with the aerodynamic size and (2) only one sampling is needed to provide a calibration point. Using this technique, a two-stage virtual impactor can be used as the sampling inlet of an OPC for aerodynamic calibration of aerosols in the field</abstract>
<note type="statement of responsibility">B.T. Chen, J.A. Tang and H.C. Yeh</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080549534">
<topic>Aerosoles</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616441">
<topic>Contaminación atmosférica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080555238">
<topic>Metrología</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080536770">
<topic>OPC</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080607609">
<topic>Partículas ambientales</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080551797">
<topic>Muestreos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080613655">
<topic>Control de contaminantes</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<originInfo>
<publisher>Akron, Ohio</publisher>
</originInfo>
<part>
<text>Vol. 51, nº 1, January 1990 ; p. 32-35</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940713</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120220.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071020414</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>