Búsqueda

Electrostatic effects in asbestos sampling I : experimental measurements

Fichero PDF / PDF file
MAP20071020483
Baron, Paul A.
Electrostatic effects in asbestos sampling I : experimental measurements / Paul A. Baron and Gregory J. Deye
Sumario: Electrostatic charge can cause errors during sampling of airborne asbestos fibers and other particles. The change in particle trajectories caused by charge effects during sampling can result in nonuniform deposits on the collecting filter surface and net loss of sample. The degree of these electrostatic effects depends on particle charge, sampler charge, sampler conductivity, and sampling flow rate and direction. The purpose of this research was to evaluate the dependence of sampling efficiency and sample uniformity on these variables. Humidity has been postulated as a primary determinant of particle charge during aerosol generation
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 2, February 1990 ; p. 51-62
1. Higiene industrial . 2. Contaminantes químicos . 3. Amianto . 4. Partículas ambientales . 5. Electricidad estática . 6. Humedad . 7. Muestreos . I. Deye, Gregory J. . II. Título. III. Título: American Industrial Hygiene Association journal.