Búsqueda

Exposition professionnelle et prévention lors de la réhabilitation d'un site industriel pollué

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071022307</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120707.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">950426e19950101fra||||    | |00010|fre d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800002627</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Exposition professionnelle et prévention lors de la réhabilitation d'un site industriel pollué</subfield>
      <subfield code="c">M. Héry... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Au cours des opérations de réhabilitation d'une décharge non non contrôlée de produits chimiques, un suivi des conditions d'hygiène et de sécurité des opérateurs a été effectué. Au plan de l'organisation du chantier, on a insisté sur une séparation en zones selon les activités, sur le respect des règles de sécurité des travaux publics, et sur la nécessité du port de protections respiratoires. Une évaluation des expositions aux polluants chimiques a également été réalisée. On a ainsi mis en évidence la grande diversité des polluants, généralement présents en quantités relativement faibles dans l'atmosphère, mais avec une pollution totale significative</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080556945</subfield>
      <subfield code="a">Vertederos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560539</subfield>
      <subfield code="a">Saneamiento</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613594</subfield>
      <subfield code="a">Contaminación industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080570484</subfield>
      <subfield code="a">Riesgo laboral</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080623470</subfield>
      <subfield code="a">Productos tóxicos y peligrosos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605155</subfield>
      <subfield code="a">Condiciones de trabajo</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080001629</subfield>
      <subfield code="a">Héry, M.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Cahiers de notes documentaires</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Cahiers de notes documentaires</subfield>
      <subfield code="d">Paris</subfield>
      <subfield code="g">nº 158, 1e. trimestre 1995 ; p. 5-13</subfield>
    </datafield>
  </record>
</collection>