Búsqueda

Determinations of known respirator leakage using controlled negative pressure and ambient aerosol QNFT systems

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071022379</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120718.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">950505e19950101usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013263</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Determinations of known respirator leakage using controlled negative pressure and ambient aerosol QNFT systems</subfield>
      <subfield code="c">Clifton D. Crutchfield... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">This study was not designed as a direct comparison of fit-factor measurements made with controlled negative pressure (CNP) and ambient aerosol fit-test systems. The study was designed to determine how well each system could measure a known source of leakage introduced into a subject's respirator</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080588946</subfield>
      <subfield code="a">Ambiente de trabajo</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080564544</subfield>
      <subfield code="a">Ventiladores</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080549534</subfield>
      <subfield code="a">Aerosoles</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080612597</subfield>
      <subfield code="a">Sistemas de ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080625016</subfield>
      <subfield code="a">Sistemas de limpieza del aire</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080586331</subfield>
      <subfield code="a">Métodos analíticos</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080316594</subfield>
      <subfield code="a">Crutchfield, Clifton D.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 56, nº 1, January 1995 ; p. 16-23</subfield>
    </datafield>
  </record>
</collection>