Aerodynamic characteristics and design guidelines of push-pull ventilation systems
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071506582</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418125149.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">050408e20050101gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003085</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080045753</subfield>
<subfield code="a">Huang, R. F.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Aerodynamic characteristics and design guidelines of push-pull ventilation systems</subfield>
<subfield code="c">R. F. Huang... [et al]</subfield>
</datafield>
<datafield tag="520" ind1="8" ind2=" ">
<subfield code="a">Aerodynamic characteristics such as the flow patterns, velocity field, streamline evolutions, characteristic flow modes and characteristic flow regimes of the push-pull ventilation system are cross-examined by using the laser-light sheet smoked-flow visualization method and laser doppler velocimetry. Four characteristic flow modes, which are denoted as dispersion, transition, encapsulation and strong suction, are identified in the domain of the push-jet and pull-flow velocities at various open-surface tank widths and rising gas velocities</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080612597</subfield>
<subfield code="a">Sistemas de ventilación</subfield>
</datafield>
<datafield tag="650" ind1="0" ind2="1">
<subfield code="0">MAPA20080601492</subfield>
<subfield code="a">Estudios comparativos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080565817</subfield>
<subfield code="a">Gases tóxicos</subfield>
</datafield>
<datafield tag="650" ind1="0" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080045753</subfield>
<subfield code="a">Huang, R. F.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford : Oxford University Press</subfield>
<subfield code="g">Vol. 49, nº 1, January 2005 ; p. 1-15</subfield>
</datafield>
</record>
</collection>