The Optimum diameter for a globe thermometer for use indoors
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Valor |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071017152 | ||
003 | MAP | ||
005 | 20080418114941.0 | ||
007 | hzruuu---uuuu | ||
008 | 940204e19771001gbr|||| | |00010|eng d | ||
035 | $a6800003075 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080134952$aHumphreys, M.A. | |
245 | 1 | 4 | $aThe Optimum diameter for a globe thermometer for use indoors$cM.A. Humphreys |
520 | $aBy applying currently recommended formulae for the heat transfer from spheres and comparing results with up-to-date information about human response to air temperature and mean radiant temperature, it is shown that the optimum diameter for a globe thermometer, when used as an index of subjective warmth for people in buildings, is approximately 40 mm. The practical performance of such a globe thermometer is described | ||
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080600488$aContaminantes físicos |
650 | 1 | 1 | $0MAPA20080538330$aCalor |
650 | 1 | 1 | $0MAPA20080613655$aControl de contaminantes |
650 | 1 | 1 | $0MAPA20080574567$aAmbiente térmico |
650 | 1 | 1 | $0MAPA20080560799$aTermometría |
650 | 1 | 1 | $0MAPA20080582135$aRadiación térmica |
650 | 1 | 1 | $0MAPA20080560768$aTemperatura |
740 | 4 | $aThe Annals of occupational hygiene | |
773 | 0 | $tThe Annals of occupational hygiene$dOxford [etc.]$gnº 2, October 1977 ; p. 135-140 |