The Assessment of a modification to the acetone/triacetin clearing technique as used in the measurement of airborne asbestos dust
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Valor |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071017562 | ||
003 | MAP | ||
005 | 20080418115111.0 | ||
007 | hzruuu---uuuu | ||
008 | 940222s1985 gbr|||| | |00010|eng d | ||
035 | $a6800003362 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080069209$aFurness, I.W. | |
245 | 1 | 4 | $aThe Assessment of a modification to the acetone/triacetin clearing technique as used in the measurement of airborne asbestos dust$cI.W. Furness and P.J. Reed |
520 | $aAn assessment is made of a modification to the acetone/triacetin clearing tecnique which shortens the time required to estimate asbestos fibre concentrations when using the membrane filter method. The modified technique, which is described in the Asbestos International Association reference method but not referred to in the equivalent Australian code, is found to provide acceptable results with no loss of accuracy | ||
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
650 | 1 | 1 | $0MAPA20080542832$aAmianto |
650 | 1 | 1 | $0MAPA20080616441$aContaminación atmosférica |
650 | 1 | 1 | $0MAPA20080621186$aControl de la contaminación |
650 | 1 | 1 | $0MAPA20080536695$aMFM |
650 | 1 | 1 | $0MAPA20080591960$aMétodos de análisis |
700 | 1 | $0MAPA20080016302$aReed, P.J. | |
740 | 4 | $aThe Annals of occupational hygiene | |
773 | 0 | $tThe Annals of occupational hygiene$dOxford [etc.]$gnº 1, 1985 ; p. 109-112 |