Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Seção: ArtigosTítulo: A Higher-flow rate cyclone for determination of respirable dust / J.R. Cossey and N.P. VaughanAutor: Cossey, J.R.Notas: Sumario: The design, testing and use of a 23 mm internal diameter cyclone for sampling of respirable dust are described. Calibration of the cyclone showed that the size selection characteristic of the cyclone gave a close match of the BMRC d50 at a flow rate of 9.2 l. min-1. On this basis, field trials were conducted at this flow rate and measurements of respirable dust and respirable silica emissions from a number of mineral processing stacks are includedRegistros relacionados: En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 1, 1987 ; p. 39-52Materia / lugar / evento: Higiene industrialContaminación atmosféricaControl de la contaminaciónPolvoMuestreadorMuestreosOtros autores: Vaughan, Nicholas P. Títulos secundários: Título: The Annals of occupational hygiene Outras classificações: 872Direitos: In Copyright (InC)