Pesquisa de referências

Performance testing of the OSIRIS dust monitoring system

Fichero PDF / PDF file
MAP20071017836
Roebuck, B.
Performance testing of the OSIRIS dust monitoring system / B. Roebuck, N.P. Vaughan and K.Y.K. Chung
Sumario: OSIRIS is a monitoring system for non-fibrous dusts based on optical scattering methods. It was developed by HSE's Safety Engineering Laboratory primarily for use in the coal-mining industry as an alternative to gravimetric sampling. Up to eight dust monitors can be controlled by a microcomputer via a two-wire telemetry link at distances of up to 8 km. The paper reports the results of comparative tests between OSIRIS and the MRE 113A gravimetric sampler in a calm air dust box, in a wind tunel and in field trials at two collieries. Results show that OSIRIS can be calibrated against the MRE 113A for a given dust and that the calibration is maintained over the normal working range of 0-40 mg m-3
En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 3, June 1990 ; p. 263-279
1. Higiene industrial . 2. Contaminantes químicos . 3. Polvo . 4. Contaminación atmosférica . 5. Control de la contaminación . 6. Muestreador . 7. MRE 113A . 8. OSIRIS . I. Vaughan, Nicholas P. . II. Chung, K.Y.K. . III. Título. IV. Título: The Annals of occupational hygiene.