Flame atomic absorption determination of manganese in whole blood using solvent extraction into acetone
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
| Tag | 1 | 2 | Valor |
|---|---|---|---|
| LDR | 00000nab a2200000 i 4500 | ||
| 001 | MAP20071019970 | ||
| 003 | MAP | ||
| 005 | 20080418120012.0 | ||
| 007 | hzruuu---uuuu | ||
| 008 | 940624e19880501usa|||| | |00010|eng d | ||
| 035 | $a6800013111 | ||
| 040 | $aMAP$bspa | ||
| 084 | $a872 | ||
| 100 | 1 | $0MAPA20080314286$aAttiyat, Abdulrahman S. | |
| 245 | 1 | 0 | $aFlame atomic absorption determination of manganese in whole blood using solvent extraction into acetone$cAbdulrahman S. Attiyat, Charles E. Matkovich and Gary D. Christian |
| 520 | $aThe authors describe here a sensitive method utilizing solvent extraction with acetone for the determination of manganese in small samples of blood. The solvent acetone has been determined to provide maximum signal enhancement for manganese | ||
| 650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
| 650 | 1 | 1 | $0MAPA20080616441$aContaminación atmosférica |
| 650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
| 650 | 1 | 1 | $0MAPA20080551551$aManganeso |
| 650 | 1 | 1 | $0MAPA20080542689$aAcetona |
| 650 | 1 | 1 | $0MAPA20080557904$aDisolventes |
| 650 | 1 | 1 | $0MAPA20080578824$aAnálisis clínicos |
| 650 | 1 | 1 | $0MAPA20080591960$aMétodos de análisis |
| 700 | 1 | $0MAPA20080287825$aMatkovich, Charles E. | |
| 700 | 1 | $0MAPA20080215224$aChristian, Gary D. | |
| 740 | 0 | $aAmerican Industrial Hygiene Association journal | |
| 773 | 0 | $tAmerican Industrial Hygiene Association journal$dAkron, Ohio$gVol. 49, nº 5, May 1988 ; p. 244-247 |