Pesquisa de referências

The Assigned protection factor of 10 for half-mask respirators

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<nonSort xml:space="preserve">The  </nonSort>
<title>Assigned protection factor of 10 for half-mask respirators</title>
</titleInfo>
<titleInfo type="alternative">
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080201814">
<namePart>Nelson, Thomas J.</namePart>
<nameIdentifier>MAPA20080201814</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<dateIssued encoding="marc">1995</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">A number of researchers have published or presented papers on workplace protection factor (WPF) studies involving half-mask respirators. Individually, each study contains a relatively small amount of data, generally less than 25 data points for any single respirator. Because of the small amount of data, any attempt to quantify the result statistically does not provide useful information on the low end of the distribution of WPFs. Several studies on half-mask respirators were combined to yield a data set with 390 observations</abstract>
<note type="statement of responsibility">Thomas J. Nelson</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080629724">
<topic>Seguridad e higiene en el trabajo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080628048">
<topic>Equipos de protección individual</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080559366">
<topic>Mascarillas</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080614942">
<topic>Prevención de accidentes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080596569">
<topic>Evaluación higiénica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591960">
<topic>Métodos de análisis</topic>
</subject>
<classification authority="">871</classification>
<relatedItem type="host">
<titleInfo>
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<originInfo>
<publisher>Akron, Ohio</publisher>
</originInfo>
<part>
<text>Vol. 56, nº 7, July 1995 ; p. 717-724</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">950911</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120823.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071023201</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>