Pesquisa de referências

Modelling of respirable dust concentrations in brickworks with a multiple cell ventilation model as an expedient for control measures

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Modelling of respirable dust concentrations in brickworks with a multiple cell ventilation model as an expedient for control measures</title>
</titleInfo>
<titleInfo type="alternative">
<title>The Annals of occupational hygiene</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080021313">
<namePart>Buringh, E.</namePart>
<nameIdentifier>MAPA20080021313</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080123239">
<namePart>Belt, R. van de</namePart>
<nameIdentifier>MAPA20080123239</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080209773">
<namePart>Wal, J.F. van der</namePart>
<nameIdentifier>MAPA20080209773</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1990</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">This paper describes a case study where a multiple cell model is used to predict airborne concentrations in enclusures and to show how the predictions can be used to devise a control strategy. The case concerns two brickworks in the Netherlands. With a quartz content of approximately 15% in the respirable dust, the respirable dust concentrations should not exceed the value of 1 mg m exp.(-3). The model is shown to give reasonable estimates of ambient respirable dust concentrations in different situations. The effectiveness of control measures can also be estimated and the importance of good housekeeping is demonstrated. The model is restricted to ambient concentrations: when there is a good correlation between personal nad ambient concentrations it could be used to predict personal exposures. The model is also used to simulate "worst case" conditions with low ventilation rates, and to evaluate the effectiveness of controls under these conditions</abstract>
<note type="statement of responsibility">E. Buringh, R. Van De Belt and J.F. Van Der Wal</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539566">
<topic>Polvo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080603137">
<topic>Procesos industriales</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080619855">
<topic>Materiales de construcción</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080551476">
<topic>Ladrillos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616441">
<topic>Contaminación atmosférica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080621186">
<topic>Control de la contaminación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080571566">
<topic>Casos prácticos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560997">
<topic>Ventilación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080586355">
<topic>Métodos de control</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080544157">
<topic>Holanda</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>The Annals of occupational hygiene</title>
</titleInfo>
<originInfo>
<publisher>Oxford [etc.]</publisher>
</originInfo>
<part>
<text>nº 5, October 1990 ; p. 499-507</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940310</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418115217.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071017848</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>