The Control of microbiological hazards associated with air-conditioning and ventilation systems
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017449</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115050.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940218s1983 gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003305</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080008178</subfield>
<subfield code="a">Ager, B.P.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="4">
<subfield code="a">The Control of microbiological hazards associated with air-conditioning and ventilation systems</subfield>
<subfield code="c">B.P. Ager and J.A. Tickner</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Conditions favourable to the growth of microorganisms are sometimes found in mechanical ventilation and air-conditioning systems. Where such microorganisms are potentially pathogenic or allergenic, human respiratory ailments such as Legionnaires' disease and humidifier fever can result. The paper reviews the incidence of these illnesses and describes the circumstances in which the causal organisms can developed. Basic information on building services systems is given and possible means of airborne transmission of microorganisms are considered</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080613617</subfield>
<subfield code="a">Contaminantes biológicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080572877</subfield>
<subfield code="a">Microorganismos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080619480</subfield>
<subfield code="a">Enfermedades profesionales</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080612597</subfield>
<subfield code="a">Sistemas de ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080625771</subfield>
<subfield code="a">Instalaciones de climatización</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080583484</subfield>
<subfield code="a">Aire acondicionado</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080086138</subfield>
<subfield code="a">Tickner, J.A.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 4, 1983 ; p. 341-358</subfield>
</datafield>
</record>
</collection>