Search

Occupational exposure to solvents : field comparison of active and passive samplers and biological monitoring of exposed workers

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071017590
003  MAP
005  20080418115117.0
007  hzruuu---uuuu
008  940223s1986 gbr|||| | |00010|eng d
035  ‎$a‎6800003390
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
24510‎$a‎Occupational exposure to solvents‎$b‎: field comparison of active and passive samplers and biological monitoring of exposed workers‎$c‎G.B. Bartolucci... [et al.]
520  ‎$a‎Results from contemporaneous samples of solvents in air obtained using personal sampling pumps connected to activated charcoal tubes and passive dosimeters were compared. Good correlations were found between the data obtained with the two sampling systems for the three main solvents examined: styrene, toluene and n-hexane. The data showed that passive dosimeters are reliable and represent a valid alternative to tradicional active samplers
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080557904‎$a‎Disolventes
65011‎$0‎MAPA20080613839‎$a‎Disolventes industriales
65011‎$0‎MAPA20080545574‎$a‎Tolueno
65011‎$0‎MAPA20080547110‎$a‎Estireno
65011‎$0‎MAPA20080548315‎$a‎N-hexano
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080613655‎$a‎Control de contaminantes
65011‎$0‎MAPA20080551797‎$a‎Muestreos
65011‎$0‎MAPA20080559670‎$a‎Muestreador
65011‎$0‎MAPA20080554040‎$a‎Dosímetros
7001 ‎$0‎MAPA20080154974‎$a‎Bartolucci, G.B.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 3, 1986 ; p. 295-306