Search

Development of a field method for evaluating the service life of organic vapor cartridges : results of laboratory testing using carbon tetrachloride

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071019337</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115752.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940524e19890901usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013182</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080159054</subfield>
      <subfield code="a">Cohen, Howard J.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Development of a field method for evaluating the service life of organic vapor cartridges</subfield>
      <subfield code="b">: results of laboratory testing using carbon tetrachloride</subfield>
      <subfield code="c">Howard J. Cohen and Richard P. Garrison</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A new method for determining the service life of respirator cartridges has been developed and tested in a laboratory setting. The method involves using small respirator carbon tubes (RCTs) packed with sorbent obtained from a respirator cartridge of interest. This method is designed to be able to determine the service life of respirator cartridges even when multiple contaminants are present in the workplace. Results of initial laboratory studies, using carbon tetrachloride as a challenge agent, indicated that RCTs were capable of predicting cartridge service life within an accuracy of 15%</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080583163</subfield>
      <subfield code="a">Vapores orgánicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080601393</subfield>
      <subfield code="a">Equipos respiratorios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080559670</subfield>
      <subfield code="a">Muestreador</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613655</subfield>
      <subfield code="a">Control de contaminantes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080602574</subfield>
      <subfield code="a">Métodos de evaluación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080612788</subfield>
      <subfield code="a">Tetracloruro de carbono</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080619022</subfield>
      <subfield code="a">Ciclo de vida del producto</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080264116</subfield>
      <subfield code="a">Garrison, Richard P.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 50, nº 9, September 1989 ; p. 486-495</subfield>
    </datafield>
  </record>
</collection>