Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Sección: ArtículosTítulo: Radon and thoron daughter working levels in British coalmines / D.W.Edlin, N.P. Crawford and J. DodgsonAutor: Edlin, D.W.Notas: Sumario: Shift-average radon and thoron daughter working levels have been measured at 11 collieries in the U.K. Levels were low (generally less than 20 milli-working levels) compared with those typical of uranium mines. The possible influences of various factors on the level of activity were examined, but a correlation was found only with ventilation distances from pit bottom to the sampling siteRegistros relacionados: En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 3, 1984 ; p. 315-320Materia / lugar / evento: Higiene industrialContaminantes químicosRadónControl de la contaminaciónMuestreosMinas de carbónGran BretañaOtros autores: Crawford, N.P. Dodgson, J. Títulos secundarios: Título: The Annals of occupational hygiene Otras clasificaciones: 872Derechos: In Copyright (InC)