Búsqueda

A comparison of light microscopy and transmission electron microscopy results in the evaluation of the occupational exposure to airborne chrysotile fibres

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017541
003  MAP
005  20080418115106.0
007  hzruuu---uuuu
008  940221s1984 gbr|||| | |00010|eng d
035  ‎$a‎6800003341
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080029333‎$a‎Marconi, A.
24512‎$a‎A comparison of light microscopy and transmission electron microscopy results in the evaluation of the occupational exposure to airborne chrysotile fibres‎$c‎A. Marconi, E. Menichini and L. Paoletti
520  ‎$a‎This paper reports a comparison between light microscopy and transmission electron microscope (TEM) counts on airborne dust samples collected during three different working processes where chrysotile was used. The results are then analyzed and discussed in comparison with the other results previously published on the same subject
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080542832‎$a‎Amianto
65011‎$0‎MAPA20080565688‎$a‎Fibra mineral
65011‎$0‎MAPA20080537050‎$a‎TEM
65011‎$0‎MAPA20080563387‎$a‎Microscopios
65011‎$0‎MAPA20080550318‎$a‎Crisotilo
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
65011‎$0‎MAPA20080601492‎$a‎Estudios comparativos
65011‎$0‎MAPA20080572884‎$a‎Minas de carbón
65011‎$0‎MAPA20080562663‎$a‎Gran Bretaña
7001 ‎$0‎MAPA20080077891‎$a‎Menichini, E.
7001 ‎$0‎MAPA20080052799‎$a‎Paoletti, L.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 3, 1984 ; p. 321-331