Búsqueda

Indoor asbestos levels on a housing estate : determined by transmission electron microscopy

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017684
003  MAP
005  20080418115136.0
007  hzruuu---uuuu
008  940307s1987 gbr|||| | |00010|eng d
035  ‎$a‎6800003081
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080004507‎$a‎Gazzi, D.
24510‎$a‎Indoor asbestos levels on a housing estate‎$b‎: determined by transmission electron microscopy‎$c‎D. Gazzi and G.W. Crockford
520  ‎$a‎The airborne asbestos fibre levels in 25 Local Authority flats containing Asbestolux board and five control dwellings with no known sources of asbestos have been determined using transmission electron microscopy (TEM). Low levels of airborne asbestos fibres were found in the Asbestolux flats, but no such fibres were found in the control flats. The predominant type of asbestos fibres found (amosite) indicated that the Asbestolux board was the source of many of the fibres
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080542832‎$a‎Amianto
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
65011‎$0‎MAPA20080551797‎$a‎Muestreos
65011‎$0‎MAPA20080537050‎$a‎TEM
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
7001 ‎$0‎MAPA20080127930‎$a‎Crockford, G.W.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 4A, 1987 ; p. 429-439