Búsqueda

Rapids XRD analysis of quartz in airborne dust samples using computer control

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Rapids XRD analysis of quartz in airborne dust samples using computer control</title>
</titleInfo>
<titleInfo type="alternative">
<title>The Annals of occupational hygiene</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080013608">
<namePart>Knight, G.</namePart>
<nameIdentifier>MAPA20080013608</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1987</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The objectives of adding computer control to the X-ray diffraction analysis developed for assessing quartz in airborne dust samples collected in mines were two-fold. First, to minimize counting time: samples with a lot of quartz required scanning of the peak over 3º 2 angles for a short counting time, whereas samples with little quartz required a longer counting time over a narrower scan. Thus both required feedback control to reduce average sample analysis time. Second, interference was frequent and variable even in one mine: to control this it was desirable to analyse on two or more diffraction lines. The computer control was set up to run each sample on up to four diffraction lines, stopping when any pair of lines gave results agreeing within the limits of error chosen</abstract>
<note type="statement of responsibility">C. Knight</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616441">
<topic>Contaminación atmosférica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080621186">
<topic>Control de la contaminación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080540760">
<topic>Cuarzo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080573324">
<topic>Polvo de cuarzo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080545192">
<topic>Rayos X</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080553975">
<topic>Difracción</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591960">
<topic>Métodos de análisis</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080608651">
<topic>Sistemas automatizados</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>The Annals of occupational hygiene</title>
</titleInfo>
<originInfo>
<publisher>Oxford [etc.]</publisher>
</originInfo>
<part>
<text>nº 2, 1989 ; p. 235-241</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940307</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418115149.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071017737</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>