Búsqueda

Glove permeation by semiconductor processing mixtures containing glycol-ether derivatives

Fichero PDF / PDF file
Colección: Artículos
Título: Glove permeation by semiconductor processing mixtures containing glycol-ether derivatives / Edward T. Zellers
Notas: Sumario: In this paper, the permeation behavior of several common glove materials challenged with semiconductor processing mixtures containing glycol-ether derivatives is described. Comparisons are made between the permeation of the solvents in the mixtures and the individual solvents comprising the mixturesRegistros relacionados: En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 53, nº 2, February 1992 ; p. 105-116Materia / lugar / evento: Higiene industrial Resistencia de materiales Guantes de protección Ensayos Permeabilidad Glycol-ether Líquidos peligrosos Contaminantes químicos Disolventes Métodos experimentales ASTM method F-739-85 Otros autores: Zellers, Edward T.
Títulos secundarios: Título: American Industrial Hygiene Association journal
Otras clasificaciones: 872