Evaluation of airborne asbestos fiber levels during removal and installation of valve gaskets and packing

Fichero PDF / PDF file
MAP20071020202
MacKinnery, William N.
Evaluation of airborne asbestos fiber levels during removal and installation of valve gaskets and packing / William N. McKinnery, Rex W. Moore
Sumario: This project was designed to evaluate airborne asbestos fiber levels generated during dry installation and removal of asbestos containing gaskets and packing materials. Every effort was made to simulate work practices commonly utilized by pipefitters and maintenance personnel in the past when asbestos exposures were not a concern
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 53, nº 8, August 1992 ; p. 531-532
1. Higiene industrial . 2. Contaminantes químicos . 3. Amianto . 4. Fibras . 5. Contaminación atmosférica . 6. Control de la contaminación . 7. Muestreos . I. Moore, Rex W. . II. Título. III. Título: American Industrial Hygiene Association journal.