Búsqueda

Computer simulation in the design of local exhaust hoods for shielded metal arc welding

Fichero PDF / PDF file
MAP20071020396
Tum Suden, Kimberly D.
Computer simulation in the design of local exhaust hoods for shielded metal arc welding / Kimberly D. Tum Suden, Michael R. Flynn and Randall Goodman
Sumario: Computer simulations were used to examine competing exhaust hood configurations for shielded metal arc welding. The welder's breathing zone concentration appears to be an inverse linear function of the computer-predicted hood capture efficiency. Hood aspect ratio, hood flow, and the welder's position relative to the hood all have a significant effect on the breathing zone concentration
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 3, March 1990 ; p. 115-126
1. Higiene industrial . 2. Contaminantes químicos . 3. Contaminación atmosférica . 4. Humos tóxicos . 5. Campanas de extracción . 6. Corrientes de aire . 7. Modelos matemáticos . 8. Soldadura por arco . 9. Control de la contaminación . 10. Programas informáticos . 11. Diseño . 12. Modelos de simulación . I. Flynn, Michael R. . II. Goodman, Randall . III. Título. IV. Título: American Industrial Hygiene Association journal.